Powermax + Easy Install and Setup

Introduction

This install guide we will cover how to set up a basic system with a remote keyfob, 1 door contact and 1 PIR. Adjust entry/exit delays, bell times, etc. Diagnostic testing, triggering the system and sending telephone reports.
 

Access the user menu

Press 'next' until 'USER SETTING' is displayed
Press 'ok' and enter the user code (1111 by default)
Pressing 'next' scrolls through the options in the user menu
To exit press  'Away' , the display will show  '<OK> TO EXIT'  , press 'ok'
 
 

‘User permit' function

The default for this is enabled. In this state, the user will have to allow the installer access to the installer menu. This is done by first accessing the 'user setting' menu, then selecting 'installer mode' With this disabled 'installer mode' becomes the next option after 'user setting' in the main menu.
Access the installer menu
 

Access the user menu

Press next until 'INSTALLER MODE' is displayed (if you go past it, press 'back' to back up)
Press 'ok' and enter the installer code (9999 by default)
Pressing 'next' scrolls through the options in installer mode
To exit press 'away' , the display will show '<OK> TO EXIT' , press 'ok'
 

Change the user code

  1. Important -The user and installer codes must be different
  2. Access user menu
  3. Press 'next' until 'SET USER CODES' is displayed
  4. Press 'ok'
  5. Display will show 'USER CODE l' , press 'ok'
  6. Enter new user code and press 'ok'
  7. Press 'away' and 'ok' to exit
 

Change the installer code

  1. Access the installer menu
  2. Display will show 'NEW INSTL CODE' , press 'ok'
  3. Enter new code and press 'ok'
  4. Press 'away' and 'ok' to exit.
 

Enrol a keyfob

This procedure covers only the 'code secure' MCT234. Other button transmitters are enrolled as 'WL devices'.
  1. Access installer mode
  2. Press 'next' until 'ENROLLING' is displayed
  3. Press 'ok'
  4. Press 'next' until 'ENROLL KEYFOB' is displayed
  5. Press 'ok'
  6. Enter keyfob number 1 or press next until 1 is displayed
  7. Press 'ok'
  8. Display shows 'TRANSMIT NOW'. Press one of the keyfob buttons
  9. Panel will beep and the display will show 'keyfob l' with a shaded square on the right.
  10. Press 'away' and 'ok' to exit.
  11. Test the keyfob by arming and disarming the system using the 'locked padlock' and 'unlocked padlock' buttons.
 

Enrolling wireless devices WL device

Before enrolling devices, you need to decide where they will be installed and which type of area they will protect (i.e. interior, perimeter, delay, etc. and the room name).

Note zone 1 default is 'front door' and type is 'delay 1', this means when the door is opened a delay will elapse before the alarm sounds.

We will use the default zone 1 setting, however zone 2 will need to be set to 'interior' and 'hall'. see Defining Zones.
 

Zone No.

Zone Type

Zone Name

Chime
(melody / Zone name / Off)

Default

Programmed

Default

Programmed

1 Delay 1   Front Door    
2 Delay 1   Garage    
3 Delay2   Garage Door    
4 Perimeter   Back Door    
5 Perimeter   Child Room    
6 Interior   Office    
7 Interior   Dinning Room    
8 Perimeter   Dinning Room    
9 Perimeter   Kitchen    
10 Perimeter   Living Room    
11 Interior   Living Room    
12 Interior   Bedroom    
13 Perimeter   Bedroom    
14 Perimeter   Guest Room    
15 Interior   Master Bedroom    
16 Perimeter   Master Bedroom    
17 Perimeter   Laundry Room    
18 Perimeter   Master Bathroom    
19 Perimeter   Basement    
20 Fire   Fire    
21 Fire   Fire    
22 Emergency   Emergency    
23 Emergency   Emergency    
24 24 h / silent   Basement    
25 24 h / silent   Office    
26 24 h / audible   Attic    
27 24 h /audible   Den    
28 non-alarm   Yard    
29 non-alarm   Hall    
30 non-alarm   Utility Room    
 

Enrolling types

Normal Enrol When making a transmission from the device, this should be an alarm signal. i.e. remove the magnet on a magnetic contact, or move in front of a PIR. Also on a PIR, inserting the battery will make the unit transmit
Enrol by Tamper To make a transmission in this mode, press the tamper switch on the device.
 

Enrol magnetic contact using 'normal enrol'

  1. Access installer mode
  2. Press 'next' until 'ENROLLING' is displayed
  3. Press 'ok'
  4. Press 'next' until 'ENROLL WL DEVICE' is displayed
  5. Press 'ok' until 'ZONE No --' is displayed
  6. Enter zone number 01, or press 'next' until 01 is displayed. (note, if a device is present there will be a shaded square next to the zone number. Another device cannot be enrolled to this zone)
  7. Press 'ok' , display will show 'TRANSMIT NOW'
  8. Make a transmission from the magnetic contact -refer to 'enrolling types' above
  9. Panel will beep and the display will show 'zone 01' with a shaded square to the right.
  10.  Press 'away' and 'ok' to exit
  11. Test by removing and replacing the magnet. Display will show 'FRONT DOOR OPEN/CLOSED'
 

Enrol PIR using 'enrol by tamper'

  1. Access installer mode
  2. Press 'next' until 'ENROLLING' is displayed
  3. Press 'ok'
  4. Display will show 'ENROLLING TYPE', press 'ok'
  5. Press 'next' until 'by tamper' is displayed
  6. Press 'ok' twice
  7. Press 'next' until 'ENROLL WL DEVICE' is displayed
  8. Press 'ok' until 'ZONE No --' is displayed
  9. Enter zone number 02, or press 'next' until 02 is displayed. (note, if a device is present there will be a shaded square next to the zone number. Another device cannot be enrolled to this zone)
  10. Press 'ok' ,display will show 'TRANSMIT NOW'
  11. Make a transmission from the PIR by pressing the tamper spring
  12. Panel will beep and the display will show 'ZONE 02' with a shaded square to the right. This can be confirmed by pressing the spring again -the panel will beep again.
  13. Press 'away' and 'ok' to exit.
 

Defining zone types

  1. Access installer mode
  2. Press 'next' until 'DEFINE ZONES' is displayed. Press 'ok'
  3. Enter '02' or press next until display shows 'ZONE 02'
  4. Press 'ok' , display will show Z02 TYPE'
  5. Press 'ok'
  6. Press 'next' until 'interior' is displayed. Press 'ok' twice
  7. Display will show 'Z01 NAME' , press 'ok'
  8. Press 'next' until- 'Hall' is displayed. Press 'ok' twice
  9. Display will show 'Z02 CHIME' we are not changing chime from default (off)
  10. Press 'away" and 'ok' to exit.
 

Setting an 'entry delay'

  1. Access 'installer mode'
  2. Press 'next' until 'DEFINE PANEL' is displayed. Press 'ok'
  3. Display will show '01:ENTRY DELAY l' , press 'ok'
  4. Press 'ok' until 'entry delay1 15s' is shown.
  5. Press 'ok' twice
  6. continue to next section
 

Setting an 'exit delay'

  1. Press 'next' until '03:EXIT DELAY' is displayed. Press 'ok'
  2. Press 'next' until 'exit delay 30s' is displayed (pressing 'back' instead scrolls backwards -this is quicker).
  3. Press 'ok' twice
  4. continue to next section
 

Setting 'bell time'

  1. Press 'next' until '04:BELL TIME' is displayed. Press 'ok'
  2. Press 'next' or 'back' until 'bell time 1m' is displayed
  3. Press 'ok' twice
  4. continue to next section
 

Setting 'abort time'

  1. Press 'next' until '05:ABORT TIME' is displayed
  2. Press 'ok'
  3. Press 'next' or 'back' until 'abort time 00s' is displayed
  4. Press 'ok' twice
  5. Press 'away' and 'ok' to exit
 

Testing the System

Diagnostic testing.

  1. Position the PIR either out of sight, or inside it's box for 2 minutes.
  2. Access 'installer mode'
  3. Press 'next' until 'DIAGNOSTICS' is displayed
  4. Press 'ok'
  5. 'WL SENSORS TEST' is displayed. Press 'ok'
  6. 'DIAG TESTING' is displayed. Trigger both sensors by opening the magnetic contact and moving in front of the PIR
  7. Each time a signal is received the panel will beep and display the zone name.
  8. Press 'ok' to scroll through the results 9. Press 'away' and 'ok' to exit.
 

Triggering detectors

  1. Position the PIR either out of sight, or inside it's box
  2. Arm the system 'away' -either by pressing 'away' and entering the user code, or by pressing the 'locked padlock' button on the keyfob.
  3. Wait for the exit beeps to stop
  4. Simulate the front door being opened by removing the magnet.
  5. The panel will start beeping and ask you to disarm
  6. Disarm by either pressing 'off and entering the user code, or by pressing the 'unlocked padlock' button on the keyfob.
  7. Repeat this and experiment by triggering the PIR first or after opening the door, (the alarm will sound).
 

Reporting to private telephones

  1. Access 'installer mode'
  2. Press 'next' until display shows 'DEFINE COMM'
  3. Press 'ok'
  4. Press 'next' until display shows' 17: SET PRVT TEL'
  5. Press 'ok'
  6. Display shows '1st private tel#' , press 'ok'
  7. If you have a mobile number, enter this or another landline number you wish to report too
  8. Press 'ok' twice
  9. Press 'home' ,display will show' 17: SET PRVT TEL'
  10. Press 'next' until display shows '20 REPORT>PRVT', press 'ok'
  11. Select option 'all (-op/cl)' ('next' to scroll and 'ok' twice to select)
  12. Press 'away' and 'ok' to exit
  13. Experiment by triggering the system (setting the alarm off, or tampering with a detector) the phone will ring and a voice message will be heard. Pressing '2' on the-phone acknowledges the call and the powermax will hang up.
 

Troubleshooting

 

User / Installer codes not working

  1. If you have changed the codes, make sure you are using the new one and not the default.
  2. Make sure the user and installer codes are not the same -if so, changing one of them will allow access.
 

Devices don't trigger the panel

Make sure the correct device has been enrolled. See 'deleting a device' and enrol it again.
 

PIR doesn't detect movement

Wireless PIR's have a sleep timer. After detection, the device will need 2 minutes with no movement before it will activate again.
 

Alarm sounds, but private telephone doesn't ring

  1. Check connection between the Powermax and telephone socket
  2. Make sure' ABORT TIME' is set to '00' see 'setting abort time'
  3. Repeat procedure 'reporting to private telephones'  Make sure the number is entered correctly and 'REPORT>PRVT' is not disabled
 

'Trouble' light is illuminated

Press 'SHOW/OK' button repeatedly, each time listening to the voice prompts. The reason will be announced.
 

Display shows 'NOT READY' and trouble light illuminated

Most likely cause is a door has been left open or a detector casing is not fitted. Pressing 'SHOW/OK' repeatedly and listen for '****** OPEN' , this will be the cause.
 

Deleting a device

  1. Access installer mode
  2. Press 'next' until 'ENROLLING' is displayed. Press 'ok'
  3. Press 'next' to select the type of device to delete (WL device, keyfob, 1 way keypad, siren)
  4. Press 'ok'
  5. For 'WL' devices, press 'ok' until 'ZONE No' is displayed
  6. Enter the zone/device number, or press 'next' until the number is displayed (note, if a device is present the number will have a shaded square next to it)
  7. Press 'ok'
  8. Display will show '<off> to delete'
  9. Press 'off'
  10. At this point, pressing 'ok' will allow you to transmit a new device for this zone
  11. Repeat steps 7 -10 for other devices of the same type.
  12. Press 'away' and 'ok' to exit.

 